Recent activity by MartyX Grover-
Please try using the instructions at the link below to reset the affected camera in the RealSense Viewer to its factory-new calibration values. https://github.com/realsenseai/librealsense/issues/11...
-
The image looks correct, with blue shading on the surfaces near to the camera and shifting from blue to yellow / orange to red (the furthest-away surfaces) as the distance of surfaces from the came...
-
The Hole Filling filter does seem to provide a clear improvement to your image. Does it improve further if you go to Stereo Module > Controls, find the 'Depth Units' setting and change its value ...
-
Hi JIshnu S Do you require further assistance with this case, please? Thanks!
-
Hi Niklas Schlueter Do you require further assistance with this case, please? Thanks!
-
Hi JIshnu S Do you require further assistance with this case, please? Thanks!
-
A Depth Stream Start Failure does not necessarily mean that there is a fault with the camera hardware: it can be a software related problem. If you have multiple D435 that have the same firmware d...
-
If the cameras had become significantly mis-calibrated since leaving your production area then performing the factory-reset of the calibration in the Viewer would correct that mis-calibration. If...
-
Hi Richard Li When performing On-Chip calibration, you first need to download and print out the target image at the link below and attach it to a flat surface such as a wall, then point the camera...
-
There is too much depth detail lost when the emitter and its light output is disabled to tell whether the holes are resulting from the emitter's projected dot pattern. It does seem though that it ...